Supraspinatus “Can” Tests
Caution
Poor Tissue Isolation (Specificity)
- In empty can for “ supra” 9 shoulder mm activesalamhItTimePut2020?
- During full can test 8 other mm were activesalamhItTimePut2020?
Pain is unreliable
- Hyperalgesia: Areas with increased inflammatory markers can cause unrelated areas to be sensitive to certain positions. For example the subacromial bursa has high concentrations of substance P and pro-inflammatory cytokines and is often aggravated by the Empty can testsalamhItTimePut2020?.
- Allodynia: Pain is not directly related to tissue damagesalamhItTimePut2020?.
Empty Can
AKA
- Jobe Test
- Empty Can Test
Purpose
Designed to evaluate for both SIS and supraspinatus pathology.
Technique
To perform this test, the clinician abducts the patient’s arm to 90 degrees in the scapular plane (30 degrees from the coronal plane) and internally rotates the wrist so that the thumb is facing the ground with the elbow extended. The clinician then applies a gentle downward force to the patient’s distal forearm, and if pain is reproduced, the test is considered positive.
Validity
Michener et al.,122 in a prospective study comparing the diagnostic reliability and accuracy of five examination tests for SIS, demonstrated a sensitivity of 50% and specificity of 87% for the Jobe test1.
Full Can
1.
Dutton M. Dutton’s Orthopaedic Examination, Evaluation, and Intervention. 5th ed. McGraw Hill Education; 2020.
Citation
For attribution, please cite this work as:
Yomogida N, Kerstein C. Supraspinatus
“Can” Tests. https://yomokerst.com/The
Archive/Examination/Tests and Measures/Upper Extremity Tests/Shoulder
Tests/supraspinatus_can_tests.html